Technologically Advanced
and Innovative Power Solutions

About Us

Trilogy LLC is a United States based company. Our Engineering staff posses over 60 years of combined experience in the fields of data center design, critical power and electrical engineering. Trilogy is a leader in innovative and industry-changing products for data centers and IT rooms with many patents and patent pending designs. Our products are engineered to provide data centers with an unparalleled, redundant, reliable and efficient products and solutions.

The HPDU &RPDU are designed to provide power to a row of racks. The input power connection consists of one input circuit for 1N models and two input circuits for 2N models. The output distribution circuits are plug and play receptacles with modular and pluggable capability in the HPDU models.

Our History

In 2001 under our previous name Millennium 2000 Technologies we released our first break through product the RPDU that was an industry changing power distribution product.  The RPDU changed the world of data centers from conventional wiring of the PDUs to the racks to a high power distribution within the rack rows.  We can proudly and simply say that we did it first, and now we are doing it again.

Our Philosophy

Our philosophy is to engineer and provide the industry with break through product that provide technologically advanced and innovative power solutions.By working closely with data centers and critical power engineering firms world wide we have witnessed a variety of issues in the area of power distribution and redundancy. Many of which, is the result of utilizing old distribution products for new and advanced data center equipment.

Advantages

Many other advantages and benefits are associated with the HPDU and RPDU distribution method.

Real Estate

The HPDU & RPDU will free valuable computer room space, which is usually occupied by bulky distribution equipment and NEC required clearances around panels.

Installation Cost

Power distribution is costly, and circuit wiring could cost several thousand of dollars. The HPDU and RPDU addresses this issue by delivering 207 KVA of plug and play receptacles powering up to 16 racks with only one input circuit.

Installation Time

Conventional wiring could take several days to complete, while the HPDU & RPDU power distribution can be available within a few hours due to the simplicity of the installation.

Quality

Field installed circuits are usually not load tested, therefore reducing the reliability and quality of the distribution circuits and increasing the chance of future failures. The HPDU & RPDU distribution unit is load tested and each individual receptacle is loaded to 100% of its capacity.

Flexibility

Addition of future circuits in a computer room requires downtime and additional cost. By using the HPDU & RPDU, load addition is easy, just plug the new equipment in to an available receptacle.

Relocation and reconfiguration

The HPDU & RDPU can be easily relocated at no additional cost to the end user. Where as in conventional wiring, a total abandonment of the distribution circuits is expected.

Air Conditioning

Conduits under computer room floors restrict AC airflow, thus resulting in added cost for additional AC units. By utilizing the RPDU or HPDU distribution, under floor congestion will be resolved.

Fire Suppression

By using the HPDU & RPDU distribution, all receptacles are above the computer room floor, which will eliminate the need for fire suppression system required by the city fire codes.

Branch Circuit Monitor Option

The HPDU & RPDU can be equipped with a Branch Circuit Monitor. The HPDU & RPDU monitor the current draw of each individual circuit. Each circuit can be programmed to provide a warning and a critical alarm. All data is transmitted to a computer or network (Modbus host) for management and monitoring. Up to 63 HPDU or RPDUs can be networked on one Modbus for simple wiring.

Load Monitoring

The RPDU is equipped with an advanced power and energy meter that monitors the total power to the RPDU. The HPDU is equipped with a current meter for each output receptacle.

Universal Operation

The HPDU & RPDU operates as a single or three phase distribution, and interfaces with a variety of AC power supply systems.

Remote Equipment Connection

The RPDU has knockouts on the top and bottom panels, and spare circuits to distribute power to any location in the computer room.